Symmetra PX 500kW Scalable to 500kW without Maintenance Bypass or Distribution-Parallel Capable

  • A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers…

  • Includes: Assembly service, Installation guide, Network Management Card, Start-Up Service, User Manual

SY500K500D Features

Symmetra PX 500kW Scalable to 500kW without Maintenance Bypass or Distribution-Parallel Capable
A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers and mission-critical environments. Multiple UPSs can be installed in parallel for ultra-efficient system redundancy or up to 2MW of power protection. Parallel installations with custom switchgear and installations using a 3rd-party maintenance bypass panel require the APC Symmetra PX250/500 Third Party Switchgear Kit for breaker monitoring and EPO functionality.
Includes: Assembly service, Installation guide, Network Management Card, Start-Up Service, User Manual

 

  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Battery modules connected in parallel
    Delivers higher availability through redundant batteries.
  • Battery replacement without tools
    Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
  • Dual mains input
    Increases availability by allowing the UPS to be connected to two separate power sources.
  • ECO Mode
    Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
  • Front-access servicing
    Simplifies installation and UPS maintenance while minimizing space requirements.
  • Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • LCD graphics touch screen display
    Full color text and mimic diagrams that easily display modes of operation, systems parameters and alarms.
  • Mega Tie
    During maintenance procedures, maintain full protection by transferring the load from one independent Symmetra PX 250/500kW system to another.
  • Output synchronization to external source
    UPS systems can be synchronized with any other independent source for use with downstream static transfer switches.
  • Parallel-capacity capable
    Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
  • Parallel-redundant capable
    Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy
  • Remote Display
    Download the display interface to your laptop or personal computer. Remotely monitor the UPS and configure a sub-set of UPS parameters. Note: Remote start-up and shutdown are not supported.
  • Scalable runtime
    Allows additional run time to be quickly added as needed.
  • Supports 3rd party maintenance bypass
    The APC Symmetra PX250/500 Third Party Switchgear Kit is required for installations with custom switchgear or a 3rd-party maintenance bypass panel. The boards in this kit monitor the breakers and provide EPO functionality.
  • Swappable batteries
    Allows quick addition of runtime capacity or replacement of existing battery modules. Installed modules are automatically recognized by the system.
  • Temperature-compensated battery charging
    Prolongs battery life by regulating the charge voltage according to battery temperature.

 

Symmetra PX Features & Benefits

Marketing Features

Generator compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.
Fully-rated power kVA equals kW

Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
Network manageable

Provides remote power management of the UPS over the network.
User-replaceable batteries

Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Configurable for N+1 internal redundancy

Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
User-replaceable power modules

Enables simple upgrades and replacements of the Power Modules.
Modular design

Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Scalable power capacity

Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
Battery modules connected in parallel

Delivers higher availability through redundant batteries.
Power Modules connected in parallel

Enhances availability by allowing immediate, seamless recovery from isolated module failures.

Agility

Programmable frequency

Ensures compatibility with different input frequencies.
Scalable power capacity

Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
SmartSlot

Customize UPS capabilities with management cards.

Sustainability

EU CoC for UPS

Ensures that UPSs sold in the EU are highly efficient
ENERGY STAR for UPS

Establishes that the efficiency of the UPS is in the top 25% of the market as verified by third party testing

Availability

Modular design

Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
Swappable power modules

Allows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.
Configurable for N+1 internal redundancy

Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Power Modules connected in parallel

Enhances availability by allowing immediate, seamless recovery from isolated module failures.
Redundant Intelligence Modules

Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Automatic internal bypass

Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Network manageable

Provides remote power management of the UPS over the network.

Manageability

Audible alarms

Provides notification of changing utility power and UPS power conditions
LED status indicators

Quickly understand unit and power status with visual indicators.
Integrates with StruxureWare Data Center Expert

An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

otal Cost of Ownership

5x8 Start-up service included

Required for full coverage of factory warranty
Generator compatible

Ensures clean, uninterrupted power to protected equipment when generator power is used.
Input power factor correction

Minimizes installation costs by enabling the use of smaller generators and cabling.
Fully-rated power kVA equals kW

Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.

Output

Output power capacity

500.0 KWatts / 500.0 kVA
Max Configurable Power (Watts)

500.0 KWatts / 500.0 kVA
Nominal Output Voltage

400V 3PH, 480V 3PH
Output Voltage Distortion

Less than 2%
Output Frequency (sync to mains)

50 Hz, 60 Hz
Output Frequency (not synced)

60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Other Output Voltages

380, 415
Topology

Double Conversion Online
Waveform type

Sine wave
Overload Operation

10 minutes @ 125% and 60 seconds @ 150%
Output Voltage THD

< 2% linear load and <3% non-linear load
Output Voltage Tolerance

+/-1% static and +/- 5% at 100% load step
Transfer Time

2ms typical
Bypass

Built-in Static Bypass

Input

Nominal Input Voltage

400V 3PH, 480V 3PH
Input frequency

40 - 70 Hz (auto sensing)
Input Connections

Hard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations

340 - 460 (400V), 408 - 552 (480)V
Input Total Harmonic Distortion

Less than 5% for full load
Type of Input Protection Required

3-pole breaker
Other Input Voltages

415
Maximum Short Circuit Withstand (Icw)

50.0kAmps
Input Power Factor at Full Load

0.99

Batteries & Runtime

Battery type

VRLA
Included Battery Modules

32
Typical recharge time

3.5hour(s)
RBC Quantity

6
Extendable Run Time

1
Efficiency in Battery Operation

96.0 %
Overload Operation

10 minutes @ 125% and 60 seconds @ 150%

Communications & Management

Interface Port(s)

SYPX250-500_Parallel
Control panel

Touch Screen LCD User Interface
Emergency Power Off (EPO)

Optional
Available SmartSlot™ Interface Quantity

1

Physical

Maximum Height

78.39inches (1991mm, 199.1CM)
Maximum Width

188.98inches (4800mm, 480.0CM)
Maximum Depth

42.13inches (1070mm, 107.0CM)
Net Weight

17947.6lbs. (8158.0KG)
Shipping weight

19661.4lbs. (8937.0KG)
Shipping Height

84.65inches (2150mm, 215.0CM)
Shipping Width

279.53inches (7100mm, 710.0CM)
Shipping Depth

50.0inches (1270mm, 127.0CM)

 

Color

Black

Environmental

Operating Temperature

32 - 104 °F (0 - 40 °C)
Operating Relative Humidity

0 - 95 %
Operating Elevation

0-3333ft (0-999.9meters)
Storage Temperature

-15 - 40 °C
Storage Relative Humidity

0 - 95 %
Storage Elevation

0-50000ft (0-15000meters)
Audible noise at 1 meter from surface of unit

54.0dBA
Online thermal dissipation

61893.0BTU/hr
Protection Class

NEMA 1, IP 20

Conformance

Approvals

cUL Listed, CSA C22.2 No.107.3-05, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, Eurobat General Purpose, OSHPD, UL 1778, UL 60950-1, UL Listed

 

Standard warranty

1 year on-site repair or replace with factory authorized Start-UP

Sustainable Offer Status

Proposition 65 Warning

Available in Documentation tab